MSO-19 USB 2GSa/s Oscilloscope, 200MSa/s Logic Analyzer, 100MSa/s Pattern Generator and TDR

We're sorry this product has been discontinued. Please choose from the menu on the left for alternative products.

MSO-19 USB 2GSa/s Oscilloscope, 200MSa/s Logic Analyzer, 100MSa/s Pattern Generator and TDR More Like This The MSO-19 is a portable USB based 2GSa/s Oscilloscope, 200MSa/s Logic Analyzer, 100MSa/s Pattern Generator and TDR. All channels sample simultaneously at a max rate of 200MSa/s (5ns), includes probe, clips, wires and software. The device works with Windows XP/Vista/7/8. The MSO-19 has time synchronized oscilloscope and logic analyzer inputs. All 9 channels are sampled at the same time and are displayed together. This is better than separate instruments because the analog and digital waveforms are acquired with the same sample clock assuring accurate time correlation between the two. Even if you went through the effort of cabling two individual instruments together, you would not be able to get the samples to within 5 ns of each other, nor would the triggering be so tightly coupled. Since the software displays the oscilloscope and logic analyzer data on the same screen it stays synchronized no matter how you scroll or zoom.

The MSO-19 can trigger on the Oscilloscope, Logic Analyzer, SPI or I2C inputs. Since all of the 9 inputs sample at the same time you will see a fully synchronized display of all the digital and analog inputs. Oscilloscope trigger: Rising edge, falling edge and pulse width. Logic Analyzer trigger: 8 bit trigger word, SPI trigger: 32 bit trigger word, I2c trigger: 32 bit trigger word. The 100Mpt/S pattern generator has many features not found on other pattern generators.  Since it has shared pins with the Logic Analyzer the pattern data can be tri-stated to create bidirectional bus signals.  The PG also runs on an independent clock from the logic analyzer, hence you can create a slow signal and analyze the response at a much faster sampling rate.  The pattern buffer length is adjustable and can be looped to create complex patterns.  The PG can start manually or be synchronized with the MSO trigger inputs. High speed sampling is key to getting a good capture.  The 200MSa single shot sample rate and 60MHz bandwidth will allow you see a great picture of a 60MHz signal in single shot mode and an even faster one if you use RIS mode sampling. The FFT Spectrum Analyzer has controls for FFT window, FFT type, FFT resolution. The software also supports averaging, memory and plot subtraction.  This allows for a whole range of spectral analysis including: Frequency response analysis, Power supply noise analysis, etc...  

Checkout
Part Number and Description Price Add to Cart
USB-MSO-19 MSO-19 USB 2GSa/s Oscilloscope, 200MSa/s Logic Analyzer, 100MSa/s Pattern Generator and TDR N/A SOLD OUT

Features and Specifications

Win32

CE Mark

USB Logo

Vista Ready

Seven Ready

Eight Ready

Features
  • USB 2.0 full-Speed for 60MHz bandwidth
  • 1 Oscilloscope and 8 Logic Analyzer Inputs
  • High speed sampling with 200 MSa/S single shot and 1GSa/S repetitive mode
  • Advanced Triggering modes include: Level/edge; Glitch; Pulse width; 8 bit Logic Analyzer; SPI; I2C
  • Data can be saved to disk and reloaded in the future or exported in CSV format for use with other software (Excel, Mathcad, etc.)
  • FrontPanelT™ Oscilloscope software supports Windows
  • Automatic Storage with save and export capabilities
  • USB bus powered and auto-setup
  • 100MHz Spectrum Analyzer/FFT
  • 100Mpt/s Pattern Generator
  • Fast, Accurate Measurements
  • SPI and I2C decoding
  • Simple Operation
Warranty Information
  • 1 Year Limited Warranty
Timebase
  • 200MSa/s to 100Sa/s; 5nS/sample to 10mS/sample; 50nS/division to 100mS/division
  • Rate (Repetitive): 2GSa/s and 1GSa/s; 5nS/division to 100nS/division
  • Accuracy: ± 0.01%
  • Resolution: 5ns
  • Skew: < 5 ns
Inputs
  • Inputs: 1 DSO + 8 Logic Analyzer
Outputs
  • Inputs: 8 Pattern Generator + 1 Trigger out (TTL)
Oscilloscope (Analog)
  • Bandwidth: 60MHz
  • Gain Range (per division) full scale = 8 divisions
    • 1x Probe / 50mV to 500mV per division / 400mV to 4V Full scale voltage
    • 10x Probe / 500mV to 5V per division / 4V to 40V
  • Max Input Voltage*
    • * max input voltage at probe tip depends on probe type (1x and 10x)
    • Probe: BNC / Continuous: ± 20V DC
    • Probe: 1X probe (included) / Continuous: ± 20V DC
    • Probe: 10X probe (included) / Continuous: ± 200V DC
  • Vertical Range: 8 divisions
  • Offset Range: ± 4 divisions
  • Offset Resolution: 12.5mV
  • Coupling: AC and DC
  • Impedance: 1MΩ // 15pF
  • DC Accuracy: ± 2%
  • Memory channel: Yes
Logic Analyzer (Digital)
  • Impedance: 100K ohm || 2pF
  • Sensitivity: <500 mv
  • Max. input voltage: +5.5V DC
  • Bandwidth: 100MHz
  • Threshold voltage: 0.6V to 1.65V (1.2, 1.5, 1.8,2.5,3.0, 3.3, 5.0V Logic Families)
  • Memory channels: Yes
SPI
  • Trigger: Yes, 32 bit wide trigger word, Mode 0..3 supported
  • Decoding window: Yes
I2C
  • Trigger: Yes, 32 bit wide trigger word
  • Decoding window: Yes
Pattern Generator (Digital output) (Digital word generator)
  • Rate: 100MSa/s...10KSa/s
  • Buffer Size: Max: 1023 points  to 3  points
  • Arming control: Sync with MSO trigger, sync with MSO arm and manual start.
  • Loop control: Continuous and variable.
  • Code generation wizard: SPI, Counter, clock…
  • Output level: Max 3.3V. 6 software selectable levels.; (1.2, 1.5, 1.8,2.5,3.0, 3.3, 5.0V Logic Families); Current drive 14ma/pin
  • Output control: Individual channel and sample by sample output enable.
Spectrum Analyzer (FFT)
  • Frequency range: 0..100MHz
  • Resolution: 0.098Hz to 195KHz depending on frequency range setting
  • Window: Rectangular, Tapered Rectangular, Triangular, Hamming, Hanning, Flat top and Blackman-Harris
  • Plot: Magnitude, Power Spectrum, Power Density, Real and Imaginary
  • Zoom: Vertical and Horizontal
  • Memory channel: Yes
  • Averaging channel: Yes
  • Cursors and Measurements: 2
Memory
  • Buffer Size: 1000 points/channel
Trigger
  • Type: Rising Edge (Adjustable level); Falling Edge (Adjustable level); Pulse Width; 8 bit wide Logic Analyzer; I2C; SPI
  • Position (pre/mid/post): Fully adjustable to anywhere in the buffer
  • External trigger input: Any of the digital inputs can be used as an external trigger
  • External trigger out: Yes
  • Mode: Auto, Normal and Single
  • Autosetup: Yes
  • Range (vertical): 8 divisions
  • Resolution: 12.5mV
Software
  • Windows XP/Vista/win7/win8: Yes
  • Spectrum Analysis / FFT: Yes
  • Measurements: Yes.
Physical Characteristics
  • Interface: USB
  • Probes: One 1x/10x switchable probe is included
  • Connectors: BNC: 2 total: Input and trig-out; Logic Analyzer/Pattern Generator: 8: USB
  • Calibration point: Yes
  • Power Requirement: USB powered
Dimensions
  • Dimensions: 102 x 61 x 20mm (4.0" x 2.4" x 0.8")
  • Weight: 70g (2.5oz.) (MSO only)
  • Shipping: Shipping box: 9" x 6" x 2" / Shipping weight: 14oz.
Package Includes
  • Includes: MSO, oscilloscope probe, wire harness, logic analyzer clips, USB cable

MSO-19 Deployed MSO-19 USB 2GSa/s Oscilloscope, 200MSa/s Logic Analyzer, 100MSa/s Pattern Generator and TDR All of the high speed acquisition is done with the MSO hardware, the speed of your PC is not a factor. The PC is used for display and for the user interface. If your PC is fast enough and has enough memory to run windows well, it will run our products well also. The Instrument has high speed samplers and buffers. It can acquire at up to 1 GSa/s and stores the data in it's own high speed data buffers. When these buffers are full everything is transferred to the PC.

Spectrum Analyzer/FFT MSO-19 USB 2GSa/s Oscilloscope, 200MSa/s Logic Analyzer, 100MSa/s Pattern Generator and TDR Maximum FFT frequency analysis speed of 100 MHz (with 3dB roll-off at 60MHz). FFT data can be saved to disk and exported to other programs such as Excel, Mathcad, etc. This example shows use of FFT averaging to identify and reduce noise. Image 1: Spectral plot of noisy output of an Op Amp circuit. Image 2: Average after 100 captures of the same circuit. Notice how clear the fundamental and harmonic frequencies are displayed and the random noise is suppressed. Image 3: The noise source was identified and removed.

Waveform Measurements MSO-19 USB 2GSa/s Oscilloscope, 200MSa/s Logic Analyzer, 100MSa/s Pattern Generator and TDR Standard waveform measurements are included and can be displayed on the screen right next to the traces.

SPI and I2C decoding MSO-19 USB 2GSa/s Oscilloscope, 200MSa/s Logic Analyzer, 100MSa/s Pattern Generator and TDR Display and decode SPI and I2C serial bus protocols as well as trigger on them. SPI and I2C signals can also be viewed as timing waveforms and statelist style display.

Big Screen Picture MSO-19 USB 2GSa/s Oscilloscope, 200MSa/s Logic Analyzer, 100MSa/s Pattern Generator and TDR The MSO-19 has time synchronized oscilloscope and logic analyzer inputs. All 9 channels are sampled at the same time and are displayed together. This is better than separate instruments because the analog and digital waveforms are acquired with the same sample clock assuring accurate time correlation between the two. Even if you went through the effort of cabling two individual instruments together, you would not be able to get the samples to within 5 ns of each other, nor would the triggering be so tightly coupled. Since the software displays the oscilloscope and logic analyzer data on the same screen it stays synchronized no matter how you scroll or zoom.

Support

Valid HTML 4.01 Valid CSS RSS/XML Feed Follow us on Twitter USB, Oscilloscope, Logic Analyzer